Congratulations!
You have purchased the finest radiant heater available for the heating of livestock
in agricultural animal confinement buildings.
Your new L.B. White radiant heater incorporates the benefits from the most
experienced manufacturer of heating products using state-of-the-art technology.
We, at L.B. White, thank you for your confidence in our products and welcome any
suggestions or comments you may have...call us toll free at 1-800-345-7200.
Owners Manual and Instructions
Modulating Infraconic
Agricultural Building Radiant Heaters
ATTENTION ALL USERS
This heater has been tested and approved by CSA International in accordance with AGA
Requirements for Gas Fired Brooders No. 8-94 and Canadian Gas Association
Requirememts for Gas Fired Brooders, CAN1-2.20-M85, as a direct gas-fired radiant
heater with intended use for the heating of livestock in agricultural animal confinement
buildings. If you are considering using this product for any application other than its
intended use, then please contact your fuel gas supplier, or the L.B. White Co., Inc.
150-23919
MODELS OUTPUT (Btuh) FUEL
I34 34,200
Propane Vapor
Withdrawal
or Natural Gas
Zobrazit stránku 0
1 2 3 4 5 6 ... 27 28

Shrnutí obsahu

Strany 1 - Congratulations!

Congratulations!You have purchased the finest radiant heater available for the heating of livestockin agricultural animal confinement buildings.Your n

Strany 2

1100The zone control panel is a remote mounted control systemallowing the operation of a specific amount of heaters withina certain zone of the buildi

Strany 3 - General Information

INDICATOR100ºF38ºCTHERMOSTATICHEAD1111Follow these start-up instruction steps for initial start-upbefore building repopulation. For normal

Strany 4 - Radiant Heater Specifications

It is important to clean the heater on a regular basis tomaintain proper combustion and to eliminate futureproblems.The frequency of

Strany 5 - Safety Precautions

FIG. 114. Repeat steps 2 and 3 until water runs clean.5. Remove the plastic bag. Inspect the cones andventuri tube to make sure these areas ar

Strany 6

1144Service Instructions1. Close the fuel supply valve to the heater beforeservicing unless it is necessary to have it open foryour servi

Strany 7 - Installation Instructions

HOSEADAPTERFLATSVALVE BODYADAPTER NUTADAPTERTHERMOSTATIC HEADBYPASS ORIFICEIndividual Control HeatersThe bypass orifice is located in the valv

Strany 8 - INSTALLATION LAYOUT 

1166SCREWRETAININGCLIPTHERMOCOUPLEINJECTORBODYTHERMALFUSEVENTURI TUBE This heater has two orifices. Remove only one orifice at a time for cleani

Strany 9 - GAS TRAIN ASSEMBLY

PRESSURE VALVEAPPLY LOCTITEBYPASS GASSUPPLY TUBEPILOT BUTTONCOMPRESSIONNUTPRESSURE VALVECOMPRESSION NUTINJECTOR BODYPILOT CONTROL VALVEAA.. RReemmo

Strany 10 - INSTALLING DUST FILTER

1188LEAD END OF THERMOCOUPLETHERMOFUSE5/16"COVERUPPER NUTTHERMOCOUPLELEADCOVERLOWER NUTTHERMOCOUPLE INSTALLEDUPPER RETAINING NUTKEY HOLE SLOTCOV

Strany 11 - Shut-Down Instructions

TEST KIT HOSEFUEL SUPPLY VALVE(OPEN THIS VALVE TOUSE PRESSURE GAUGE)GAS SUPPLY HOSEGAS INLET OF HEATERPRESSURE GAUGE KIT20736OPENFIG. 24AA.. PPrree

Strany 12 - Cleaning Instructions

WARNINGFire and Explosion Hazard Not for home or recreational vehicle use. Installation of this heater in a home orrecreational vehicle may result i

Strany 13 - BB.. FFIILLTTEERR

2200READ THIS ENTIRE SECTION BEFOREBEGINNING TO TROUBLESHOOT PROBLEMS.The following troubleshooting flow charts provide systematicprocedures for isol

Strany 14 - Maintenance Instructions

Is There aBlockage in theInjector Body or Venturi Tube?2211PPrroobblleemm 11IInnnneerrCCoommbbuussttiioonnCCoonnee WWiillll NNoottLLiigghhttIs Th

Strany 15 - SAFETY GAS CONTROL VALVE

2222PPrroobblleemm 22IInnnneerrCCoommbbuussttiioonnCCoonnee LLiigghhttss,,bbuutt wwiillll nnoottSSttaayy LLiittDid you Allow Sufficient Time for

Strany 16 - THERMOSTATIC HEAD

2233PPrroobblleemm 33OOuutteerrCCoommbbuussttiioonnCCoonnee DDooeessNNoott HHeeaatt UUppoonn HHiigghhTThheerrmmoossttaattSSeettttiinngg..Is Prope

Strany 17 - MAIN BURNER PRESSURE VALVE

2244Combustion Cone KitsPart Number21088NoPPrroobblleemm 55HHeeaatteerr DDooeess NNoott RReettuurrnn BBaacckk ttoo LLooww HHeeaatt..Does Main

Strany 18 - THERMOCOUPLE

2255Heater Component FunctionBurner OrificesMetering devices used to feed gas to combustion cones at aspecific flow rate.CanopyReflective aluminum hea

Strany 19 - GAS PRESSURE CHECKS

Parts IdentificationPARTS SCHEMATIC2434B353433322726252831181534A29C29A29B 5 411 3 6 916 2 2 7 1INDIVIDUAL CONTROL 36372266

Strany 20 - Troubleshooting Guide

2277PARTS LISTItem Description Part No.1 Venturi Tube and Burner Assembly 096402 Thermocouple Retaining Nut 095763 Thermocouple with Fusible Link 0959

Strany 21

Contact your local L.B. White dealer for replacement partsand ser vice or call the L.B. White Company, Inc. at 1-800-345-7200 for assis

Strany 22

This owner's manual includes all options and accessoriescommonly used on or with this heater. However, dependingon the configuration purchased,

Strany 23 - Supplied to the

I34Maximum Input (Btuh) 34,200Ventilation Air to Support Combustion 400 CFMZone Control PROPANE GAS OR 5 PSIGFull Output Pressure NATURAL GASZone Cont

Strany 24

PPrrooppaannee ggaass aanndd nnaattuurraall ggaass hhaavvee mmaann--mmaaddee ooddoorraannttss aaddddeedd ssppeecciiffiiccaallllyy ffoorr dd

Strany 25 - Heater Component Function

1. Do not attempt to install, repair or service this heateror the gas supply line unless you have continuingexpert training and knowledge of gas

Strany 26 - Parts Identification

1. Read all safety precautions and follow L. B. Whiterecommendations when installing this heater. Ifduring the installation or relocatin

Strany 27 - PARTS LIST

INSTALLATION LAYOUT FOR SAFE CLEARANCESI17 & I34 - 3 FT. MINIMUMBROODER TOP TO CEILINGPOSITION THE GAS HOSE AND ELECTRICAL POWER CORDOUTSIDE OF

Strany 28 - Replacement Parts and Service

ABCHOSE & QUICK COUPLING KITCOLLARMALE ENDCOUPLINGVALVESHUT-OFFTO GASSUPPLYBUSHINGNIPPLEDUST CAP- ASSEMBLE COUPLING KIT  COMPONENTS & TIGH